Oura Ring Gen 4 sensor data — not clinical measurementsN=1 case study — not validated for clinical decisionsHEV diagnosed Mar 18; interpret findings cautiously in this Day 8 post-ruxolitinib window

Oura Digital Twin Dashboard

Oura Gen 4: 2026-01-08 to 2026-03-23 (75 unique days, 84 sleep periods) · 10/10 analysis modules loaded · Ruxolitinib 10 mg BID from 2026-03-16
Generated 2026-03-27 07:10 · Post-HSCT Patient
POST-HSCT BIOMETRIC MONITORING

Consumer wearable suggests a physiological shift after JAK inhibitor start
exploratory N=1 monitoring in a confounded window

N/A
Lowest raw
p-value
N/A
FDR-adjusted
q-value
0/0
Streams surviving
FDR correction
33,655
Biometric readings
analyzed
Oura Ring Gen 4 · 75 days · 10/10 analysis modules · Ruxolitinib 10 mg BID from 2026-03-16
PRE
Pre-Ruxolitinib
67 days · 73 sleep periods
HR 85.1 bpm HRV 9.1 ms
POST
Post-Ruxolitinib
8 days · 11 sleep periods
HR 81.8 bpm HRV 10.1 ms
Key Finding
Analysis modules detected multiple biosignal shifts after ruxolitinib initiation, but the 8-day post-intervention window remains too short for strong causal claims. 0/0 CausalImpact streams reach raw p<0.05; 0/0 survive FDR correction. Separate UKF comparisons: Cardiac Reserve shift p=0.040, Sleep Quality shift p<0.001.
Temperature
N/A
No data
HRV (RMSSD)
9.2ms
vs healthy 42-49 ms | Kleiger 1987 / Bigger 1992
Resting HR
85bpm
IST threshold: 90 bpm
SpO2
96.1%
BOS risk: LOW (17/100)
Sleep Efficiency
73%
Below 85% threshold
Autonomic Tone
0.00SD
UKF state | improved | p=0.244
GVHD Score
15/100
7d avg: 22
Anomaly Days
8/84
Feb 9 detected (8 anomaly days, N=1)

Interrupted Time Series: Temperature Response

CausalImpact BSTS

Treatment Effect Sizes

CausalImpact + UKF

Disease State Trajectory

rSLDS 4-State Model

Anomaly Detection

5-Algorithm Ensemble

Composite Biomarker Trends

6 Biomarkers

SpO2 & BOS Risk

Pulmonary Screening

Combined Biosignal Timeline

5-Channel View

Heart Rate Terrain Map

3D Surface

Phase Space Reconstruction

Nonlinear Dynamics

Sleep Architecture Heatmap

Epoch-Level

Circadian Rhythm Analysis

Cosinor Model
Methodology & Data Provenance
Data Source
Oura Ring Gen 4 (continuous PPG, accelerometry, thermometry)
Volume
27,669 HR readings · 5,986 HRV samples · 6,382 sleep epochs
Analysis Pipeline
CausalImpact (BSTS) · Unscented Kalman Filter (5 latent states) · rSLDS (4 disease states) · 5-algorithm anomaly ensemble · 6 composite biomarkers · Chronos-2 / ARIMA forecasting
Sleep Architecture
Deep: 14.9% Light: 51.3% REM: 11.5% Awake: 22.3%
For research and clinical discussion only. Not a diagnostic tool. All p-values are exploratory.